Methanol for Gradient Liquid Chromatography

Product Specifications

Specification Details
Product Name Methanol
Brand Parna
Product Code M103G
Grade Gradient Liquid Chromatography
CAS Number 67-56-1
Synonyms Hydroxymethane, Methyl Alcohol, Carbinol
Available Packaging Sizes 1 L, 2.5 L, 20 L
Description

Methanol HPLC Grade

Methanol for Gradient Liquid Chromatography | PARENA Brand | Product Code M103G

Product Introduction

Methanol Gradient HPLC by PARENA is an organic solvent with the chemical formula CH₃OH and CAS Number 67-56-1, designed for use in High-Performance Liquid Chromatography (HPLC) methods. It is used for mobile phase preparation, chromatographic method development, analysis of organic compounds, and the implementation of isocratic and gradient elution methods.

In liquid chromatography, the quality of an organic solvent is not evaluated solely by its chemical purity percentage. UV absorbance, trace organic impurities, non-volatile residue, water content, and solvent behavior during gradient elution tests are also important parameters affecting analytical performance. These characteristics are particularly important in methods using UV or DAD detectors, where the mobile phase composition changes over time.

Methanol Gradient HPLC Grade is used as the organic mobile phase component alongside water or aqueous buffer solutions. By changing the proportion of organic solvent throughout the chromatographic program, it enables adjustment of mobile phase elution strength, modification of retention times, and improvement of separation between compounds with different physicochemical properties.

This product is supplied under the PARENA brand, product code M103G, in 1 L, 2.5 L, and 20 L packaging.

PARENA Methanol Gradient HPLC Grade suitable for liquid chromatography

PARENA Methanol Gradient HPLC Grade

What Is Methanol Gradient HPLC and What Are Its Technical Characteristics?

Methanol is one of the widely used organic solvents in liquid chromatography due to its polarity, miscibility with water, relatively suitable viscosity, and solvent properties. It is used in many chromatographic separation methods.

In Reversed-Phase HPLC methods, methanol acts as an organic modifier of the mobile phase. Increasing the proportion of methanol in the mobile phase generally increases its elution strength and may reduce the retention time of compounds. However, the magnitude and direction of its effect on separation depend on analyte structure, column type, mobile phase composition, and method conditions.

In Gradient HPLC Grade solvents, solvent quality control is particularly important for use in mobile phase composition programs. During gradient elution, a gradual or stepwise increase in methanol concentration may affect detector response and baseline behavior. UV-absorbing impurities in the solvent may appear as baseline changes, noise, or interfering signals when the solvent concentration changes during the gradient.

For this reason, solvents intended for Gradient LC are controlled not only for chemical purity but also for parameters such as UV absorbance, Gradient Elution testing, residue after evaporation, water content, and certain trace impurities. Acceptance limits for these parameters vary depending on the manufacturer, product, and test method.

The Role of Methanol in Reversed-Phase HPLC

In reversed-phase chromatography, the stationary phase usually has a relatively hydrophobic surface, such as C18, C8, or other bonded silica phases, while the mobile phase consists of water or an aqueous solution combined with an organic solvent.

Methanol, as the organic component of the mobile phase, affects the distribution equilibrium of analytes between the mobile and stationary phases. Increasing the methanol percentage in the mobile phase changes the interactions responsible for compound retention on the stationary phase and, in many RP-HPLC systems, reduces compound retention times.

Choosing methanol instead of other organic modifiers, including acetonitrile, may change selectivity, elution order, system pressure, peak shape, and resolution. Therefore, replacing methanol with acetonitrile or vice versa is not necessarily possible without changing the analytical method and usually requires evaluation and optimization of chromatographic conditions.

High-Performance Liquid Chromatography HPLC instrument

High-Performance Liquid Chromatography (HPLC) Instrument

The Role of Methanol in the Mobile Phase

  • Adjusting the elution strength of the mobile phase in reversed-phase chromatography
  • Changing compound retention times by adjusting the organic solvent percentage
  • Influencing chromatographic selectivity and resolution
  • Adjusting mobile phase composition in isocratic and gradient methods
  • Supporting the development and optimization of organic compound separation methods
  • Use in combination with water, buffer solutions, and additives compatible with the analytical method

The Importance of Gradient Grade in Chromatographic Analysis

Schematic illustration of gradient elution in HPLC liquid chromatography

Schematic illustration of the Gradient Elution process in HPLC

In an Isocratic method, the mobile phase composition remains constant throughout the analysis. In contrast, in a Gradient method, the proportions of mobile phase solvents change over time. This change in composition is used to separate mixtures containing compounds with different polarities, retention strengths, or retention times.

In gradient methods, the organic solvent quality must be compatible with changing mobile phase composition. Impurities that may have a limited effect under a constant mobile phase composition can cause baseline changes or interfering signals as the solvent percentage changes.

Key characteristics of Gradient HPLC solvents include:

1. Controlled UV Absorbance

UV-absorbing impurities in the solvent may increase background absorbance, reduce the signal-to-noise ratio, or produce unwanted signals at wavelengths used for analyte detection. UV absorbance control is particularly important in analyses performed at low wavelengths.

2. Controlled Solvent Behavior During Gradient Elution Testing

Gradient Elution testing is performed to evaluate signal or baseline changes under conditions where solvent composition changes. Suitable performance in this test is important for gradient methods that require a stable baseline.

3. Low Non-Volatile Residue

Residues remaining after solvent evaporation may cause contamination, deposits, or increased residual material in the chromatographic flow path. Control of Residue after Evaporation is important for sensitive applications.

4. Control of Water and Trace Impurities

Water content, unwanted organic compounds, and certain trace impurities may affect result reproducibility, mobile phase behavior, and method performance. The control limits for these parameters should be evaluated according to the product’s technical specifications.

Specialized Applications of Methanol Gradient HPLC

1. Mobile Phase Preparation for Reversed-Phase HPLC

Methanol is used as the organic component of the mobile phase in RP-HPLC methods, particularly in combination with water, aqueous solutions, and buffers compatible with the method. Adjusting the methanol percentage can be used to control retention time, optimize resolution, and adjust elution conditions.

2. Gradient Elution Methods

In gradient elution methods, the percentage of methanol in the mobile phase changes according to the instrument’s programmed schedule. This approach is used for analyzing mixtures containing compounds with different polarities or retention strengths and may improve elution efficiency and reduce analysis time, depending on the method conditions.

3. Pharmaceutical Analysis

Methanol Gradient HPLC is used in certain developed and validated methods for analyzing Active Pharmaceutical Ingredients (APIs), related impurities, degradation products, and compounds present in pharmaceutical formulations.

Its application in this field depends on the analytical method, column type, detector, sample solubility, and method requirements. Solvent grade selection is particularly important in methods sensitive to UV absorbance and impurity analysis.

4. Quality Control of Raw Materials and Chemical Products

In quality control laboratories, Methanol Gradient Grade may be used as a mobile phase solvent for evaluating composition, purity, impurities, and quality characteristics of chemical materials, provided that the analytical method has been designed or validated for use with this solvent.

5. Analysis of Organic Compounds and Synthetic Chemicals

In organic chemistry research, synthesis, process development, and quality control, methanol may be used for the separation and evaluation of organic compounds, reaction products, and certain related impurities.

6. Analysis of Compounds in Biological and Research Samples

In certain HPLC methods used to investigate compounds in biological samples, extracts, and research matrices, methanol is used as a mobile phase component or sample preparation solvent. Its application depends on the method, sample compatibility, and detector type.

7. Chromatographic Method Development and Optimization

Methanol is used in analytical method development to evaluate the effects of organic solvent type, solvent percentage, gradient slope, retention time, selectivity, and peak resolution. Compared with certain other organic solvents, changing the modifier type may significantly alter separation behavior.

8. Applications in HPLC and UHPLC Systems

Chromatography-grade methanol may be used in HPLC and certain UHPLC systems when its technical specifications are compatible with the analytical method and operating conditions. Solvent compatibility with operating pressure, column, equipment, method, and instrument conditions should be evaluated before use.

Differences Between Methanol Gradient HPLC and Other Methanol Grades

Different methanol grades vary in their intended applications, impurity limits, and quality control tests. Purity percentage alone is not a sufficient criterion for selecting a solvent for sensitive chromatographic applications.

Methanol Grade Main Application Important Quality Control Characteristics Suitability for HPLC
Industrial / Technical Grade Industrial and process applications Specifications appropriate for industrial use; impurity control depends on product specifications Generally not a suitable choice for sensitive HPLC applications
Laboratory / Reagent Grade General laboratory and chemical applications General purity and testing appropriate for laboratory applications Not necessarily suitable for HPLC
ACS Reagent Grade General analytical applications according to applicable requirements Compliance with ACS specifications, when declared and verified Only when Suitability for LC is confirmed
HPLC Grade / Isocratic Grade Liquid chromatography applications Control of impurities and UV absorbance according to grade specifications Suitable for LC methods according to product specifications
Gradient HPLC Grade HPLC methods involving changes in mobile phase composition UV absorbance, gradient testing, impurities, and residue control according to specifications Specialized choice for gradient methods
LC-MS Grade Liquid chromatography coupled with mass spectrometry Control of impurities affecting MS response, including certain ionic and background contaminants Suitable for LC-MS methods according to specifications; generally also usable for LC-UV, but not necessarily the best or most economical choice

Difference Between Methanol Gradient HPLC and Methanol ACS

Methanol ACS Reagent Grade is supplied for general analytical and laboratory applications according to the applicable ACS grade specifications. However, ACS compliance alone does not guarantee solvent performance in gradient HPLC methods.

In HPLC, UV-absorbing impurities may cause increased noise, baseline changes, or interfering signals during changes in mobile phase composition, even at low concentrations. Therefore, for sensitive chromatographic methods, LC-grade solvents with controlled UV absorbance specifications and chromatographic testing are generally more suitable than general-purpose ACS solvents, unless the ACS product is specifically confirmed as suitable for LC applications.

Difference Between Gradient HPLC and Isocratic HPLC Grade

LC-suitable grades may differ in their quality control tests and acceptance limits. Gradient Grade solvents are specifically relevant for methods in which mobile phase composition changes over time, particularly with regard to parameters such as Gradient Elution testing and UV absorbance.

In Isocratic methods, the mobile phase composition remains constant throughout the analysis. In gradient methods, changes in solvent proportions may reveal UV-absorbing impurities through baseline changes. Therefore, using a solvent with appropriate Gradient LC specifications is recommended for gradient methods and sensitive analyses.

Difference Between Gradient HPLC and LC-MS Grade

LC-MS Grade solvents are intended for liquid chromatography coupled with mass spectrometry. In addition to chromatographic quality, they focus on controlling impurities that may increase background signals, contaminate the ion source, or interfere with mass spectrometric response.

Gradient HPLC Grade solvents are specifically selected for chromatographic requirements and solvent behavior during gradient tests. LC-MS Grade is a more specialized choice for methods where mass spectrometer sensitivity and background contamination control are important.

Therefore, Gradient HPLC and LC-MS Grade should not be compared solely based on purity percentage. Selection should be based on detector type, analytical method, and the actual product specifications.

Technical Specifications of PARENA Methanol Gradient HPLC

Specification Value / Description
Product Name Methanol HPLC Grade
Brand PARENA
Product Code M103G
Grade Gradient Liquid Chromatography
Chemical Formula CH₃OH
CAS Number 67-56-1
Molar Mass 32.04 g/mol
Synonyms Methanol, Methyl Alcohol, Carbinol, Hydroxymethane
Physical State Liquid
Color Colorless
Melting Point Approximately −97.6 °C
Boiling Point Approximately 64.7 °C
Density Approximately 0.792 g/mL at 20 °C
Miscibility with Water Miscible in all proportions
Main Application Organic mobile phase solvent in HPLC
Specialized Applications Gradient Elution, RP-HPLC, and chromatographic method development
Packaging 1 L, 2.5 L, 20 L

Why Is Methanol Gradient HPLC Important in Sensitive Analyses?

In chromatographic analyses, solvent quality may affect method performance alongside column type, flow conditions, mobile phase composition, and detector type. Using a solvent with specifications suitable for LC may reduce the likelihood of introducing certain interfering impurities through the mobile phase.

Quality control becomes more important in gradient methods because changes in the percentage of organic solvent during the analytical program may reveal background absorbance changes caused by solvent impurities. This is particularly relevant in UV measurements, impurity analysis, and methods requiring a stable baseline.

From a solvent selection perspective, parameters such as UV absorbance at the analytical wavelength, Gradient Elution testing, non-volatile residue, and water content should be matched to the requirements of the analytical method.

Important Considerations When Selecting and Using Methanol Gradient HPLC

  • The solvent grade should be compatible with the analytical method, column type, and detector.
  • In methods using UV or DAD detectors, solvent UV absorbance at the analytical wavelength is important.
  • In gradient methods, Gradient Elution test specifications and solvent baseline behavior should be considered.
  • Water, buffer, and other mobile phase components also affect the overall performance of the method.
  • Prevent contamination of the solvent bottle and mobile phase reservoir.
  • When changing the solvent brand or grade, method performance and results should be evaluated.
  • Used solvents should be collected and disposed of according to the laboratory’s chemical waste management procedures.

Methanol Safety and Hazards

Methanol is a highly flammable and toxic liquid. Contact, inhalation, or ingestion may cause serious poisoning. Exposure to methanol may damage the central nervous system, vision, and other organs.

When working with Methanol Gradient HPLC:

  • Wear safety goggles, suitable gloves, and protective clothing.
  • Handle and transfer the solvent in a well-ventilated area, preferably under a fume hood.
  • Avoid inhalation of vapors and direct contact with skin and eyes.
  • Keep away from heat sources, flames, sparks, and hot surfaces.
  • Keep solvent containers closed after use.
  • In case of contact, exposure, or suspected ingestion, follow the SDS instructions and seek immediate medical attention.

Hazard classification, GHS symbols, and emergency measures should be reviewed according to the official product SDS.

Storage Conditions

Methanol Gradient HPLC should be stored in its original, tightly closed container in a suitable chemical storage area with adequate ventilation and away from ignition sources.

To maintain solvent quality:

  • Prevent the introduction of water, dust, and external contaminants.
  • Do not expose the container to direct heat or unsuitable sunlight.
  • Do not store near strong oxidizing agents.
  • Follow the manufacturer’s storage conditions and shelf-life recommendations as stated in the SDS.
  • For chromatographic applications, avoid transferring the solvent into contaminated or unsuitable containers.

PARENA Methanol Gradient HPLC Packaging

PARENA Methanol Gradient HPLC, product code M103G, is available in the following packaging sizes:

  • 1 Liter
  • 2.5 Liters
  • 20 Liters

The packaging size should be selected based on laboratory consumption, analysis frequency, mobile phase preparation requirements, and storage conditions.

Purchase PARENA Methanol Gradient HPLC

PARENA Methanol Gradient HPLC, product code M103G, is an option for instrumental analysis laboratories, quality control laboratories, chemical research, and liquid chromatography methods, provided that the product specifications meet the requirements of the analytical method.

When purchasing Methanol Gradient HPLC, in addition to purity percentage, chromatographic specifications such as UV absorbance, Gradient Elution testing, non-volatile residue, water content, and other impurity limits should be considered.

To inquire about the price of PARENA Methanol Gradient HPLC, check availability, select a packaging size, or request technical documentation, use the product price inquiry section. For information about other chemical supply products and services, visit the Noavaran Fidar Shimi Polymer Gostar website.

Contact the Sales Experts at Noavaran Fidar Shimi Polymer Gostar

Product Name: Methanol Gradient Grade for HPLC

Brand: PARENA

Product Code: M103G

Grade: Gradient Liquid Chromatography

CAS: 67-56-1

Packaging: 1 L, 2.5 L, 20 L

Frequently Asked Questions About PARENA Methanol Gradient HPLC

What is Methanol Gradient HPLC used for?
Methanol Gradient HPLC is used as an organic mobile phase solvent in High-Performance Liquid Chromatography (HPLC). Its main applications include mobile phase preparation, gradient methods, Reversed-Phase HPLC (RP-HPLC), and chromatographic method development for separating organic compounds.
What is the difference between Methanol Gradient HPLC and laboratory methanol?
General laboratory methanol is supplied for various chemical applications and does not necessarily have the specifications required for sensitive chromatographic methods. In Gradient HPLC Grade, in addition to chemical purity, parameters such as UV absorbance, Gradient Elution testing, and residue are controlled to ensure compatibility with gradient method requirements.
Why is Gradient Grade methanol used in gradient HPLC?
In gradient methods, the percentage of organic solvent changes over time. If the solvent contains UV-absorbing impurities, changes in mobile phase composition may cause baseline shifts, increased noise, or interfering signals. Gradient Grade solvents are intended to control these characteristics according to product specifications.
Is Methanol Gradient HPLC suitable for RP-HPLC?
Yes. Methanol is a widely used organic modifier in Reversed-Phase HPLC and may be used as a mobile phase component in combination with water or suitable aqueous solutions. The methanol percentage depends on the column type, analyte structure, method conditions, and separation objectives.
Is Methanol Gradient HPLC used for pharmaceutical analysis?
Methanol is used as a mobile phase solvent in many chromatographic methods developed for analyzing pharmaceutical active ingredients, impurities, and pharmaceutical samples. The grade used should be compatible with the analytical method and its specifications.
Is Methanol Gradient HPLC the same as Methanol LC-MS Grade?
No, they are not necessarily the same. Gradient HPLC Grade is intended for chromatographic requirements, particularly UV absorbance control and solvent behavior during gradients. LC-MS Grade additionally focuses on controlling impurities that may affect background signals, ionization, and mass spectrometer response. Grade selection should be based on the detector and analytical method.
Is Methanol Gradient HPLC miscible with water?
Yes. Methanol is miscible with water in all proportions, allowing mobile phases with different water-to-methanol ratios to be prepared for chromatographic methods.
What packaging sizes are available for PARENA Methanol Gradient HPLC?
PARENA Methanol Gradient HPLC, product code M103G, is available in 1 L, 2.5 L, and 20 L packaging.
How can I order PARENA Methanol Gradient HPLC?
To inquire about pricing, availability, technical information, or packaging sizes for PARENA Methanol Gradient HPLC, you can submit a request through the product price inquiry section or contact our sales experts.

For general chemical information about this compound, visit the Methanol page on PubChem.